Installation · Growatt

Install GridZeno on Growatt MOD TL3-HU.

The MOD TL3-HU is Growatt's three-phase hybrid inverter with battery. The signal ports are in a COM panel with five RJ45 ports and a terminal block under a waterproof cover. The dongle is plugged into Para.out, Growatt's RS485 port for parallel operation, where A is on pin 5 and B on pin 1. The inverter end is crimped with only those two wires.

Applies to
MOD 3000-15KTL3-HU
Connection
Network cable with RJ45 plug
Time
About 25 minutes

The battery is controlled with Growatt's VPP protocol: a command with power and duration, which the dongle removes itself when the block ends. What GridZeno can do on Growatt MOD TL3-HU

How the dongle recognises it: The type code 5401, MOD 3-15KTL3-HU. The dongle reads it with the MOD TL3-XH map and knows it's a MOD and not a MID because you choose MOD when you set up GridZeno.

GridZeno Dongle for Growatt MOD TL3-HU

01

What you need

GridZeno Dongle
The device ID is on the label, e.g. GZ-A1B2C3.
Cable
A network cable that's re-crimped at the inverter end with only two wires.
RJ45 plug and crimping tool
For the inverter end.
Screwdriver
Phillips, for the four screws in the waterproof cover over the COM panel.
USB power
A 5 V USB charger and a cable with USB-C.
02

The port

In the COM panel on the underside between the USB port and AC, under a waterproof cover with four screws: DRMS, BAT and Meter at the top, Para.out, Dry contact and Para.in at the bottom.

Port
Para.out (RJ45)
Pin 1: B, 485B, white/blue wire.
Pin 2: not in use.
Pin 3: not in use.
Pin 4: not in use.
Pin 5: A, 485A, blue wire.
Pin 6: not in use.
Pin 7: not in use.
Pin 8: not in use.
The Para.out port, as Growatt numbers the pins. A is on pin 5 and B on pin 1. Para.in has the same pins. The plug shown with the contacts facing you and the locking tab at the back: pin 1 is furthest to the left.
  • Pin 5 A, 485A
  • Pin 1 B, 485B

How it differs from MID-HU

MOD TL3-HU is the smaller of the two: MOD 3000-15KTL3-HU, 3-15 kW. MID-HU covers MID 29.9K-50K-HU and MID 20-30KTL3-HU-L.

They share the type code 5401. The dongle knows it's on a MOD because you choose MOD when you set up GridZeno.

On MOD TL3-HU the COM panel sits between the USB port and AC, with DRMS, BAT and Meter at the top and Para.out, Dry contact and Para.in at the bottom.

See the guide for MID-HU

03

The cable

A network cable where the inverter end is crimped with only two wires: the dongle's A (blue, pin 4) on pin 5 and B (white/blue, pin 5) on pin 1. The other positions in the connector are empty. An ordinary straight cable doesn't work here, because A and B are on pins 5 and 1, not on 4 and 5.

From the dongle to the inverter
Dongle endInverter end
Dongle pin 4, blue (A)Para.out pin 5, 485A
Dongle pin 5, white/blue (B)Para.out pin 1, 485B
The other wiresCut off and insulated
04

Settings

On the inverter

General Setting > Address
001, as from the factory
Modbus
Modbus RTU at 9600 baud, 8N1. That's what the dongle uses from the factory, so there's nothing to set.

In GridZeno's Welcome

The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.

Manufacturer and model
Growatt, MOD
Connection
By cable (RS485)
RS485 settings
Keep the default: 9600 baud, 8N1, address 1.
05

Step by step

Each step has a small drawing that shows what to do.

  1. 1
    Check the address

    Press the touch button once to scroll, and twice to select. Go to General Setting, past Language, to Address. It must be set to 001, as from the factory.

  2. 2
    Turn off the inverter, and remove the COM cover

    Switch off the AC breaker, set the DC switch to OFF, and switch off the battery's DC switch. Wait 5 minutes. The COM panel is on the underside between the USB port and AC. Unscrew the four screws in the waterproof cover.

  3. 3
    Crimp the inverter end with two wires

    Cut off the connector at the inverter end. Crimp on a new RJ45 connector with blue (A) on pin 5 and white/blue (B) on pin 1. The other wires are cut off and insulated. The other end, for the dongle, keeps its connector.

  4. 4
    Pass the cable through the cover

    Pass the cable through the waterproof cover and the threaded sleeve, and press it into the rubber ring from the side. Leave the sealing plugs in the holes that aren't used.

  5. 5
    Plug the connector into Para.out

    Press the connector into the Para.out port at the bottom left until it clicks. If Para.out is taken by a cable to another inverter, use Para.in if it's free.

  6. 6
    Screw the cover back on

    Press the rubber ring into place, screw the four screws in the cover tight, and tighten the threaded sleeve so the COM panel is sealed.

  7. 7
    Plug the RJ45 end into the dongle

    The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.

  8. 8
    Connect power to the dongle

    Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.

  9. 9
    Connect the dongle to the network

    Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.

  10. 10
    Log in, and choose your inverter

    Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Growatt MOD, and the connection By cable (RS485). Press Save inverter, and the dongle fetches its setup and reads the inverter.

The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.

06

Take care

Use Para.out or Para.in. BAT is the battery's connection, Meter the energy meter's, and DRMS is for external disconnection. They must not be used for the dongle.
Para.out and Para.in are also used when several inverters are connected in parallel with Growatt's ShineMaster or SEM. If you have that, write to us before you connect the dongle.

What GridZeno can control on Growatt MOD TL3-HU, and how, is on the page about Growatt MOD TL3-HU. If you're stuck, write to us with the model name.

07

Source

Ports, pins and menus are from the manufacturer's own manual: Growatt MOD 3-15KTL3-HU User Manual (EN, 2025-11), Figure 3-3, Appearance, 5.7.1, COM port (figure 5-8 and table 5-3), 5.7.2, Connecting the COM connector (figure 5-9), and 6.3, Setting the communication address.