Install GridZeno on Growatt MIN TL-XH2.

MIN TL-XH2 is Growatt's single-phase hybrid inverter. It comes with round connectors and with RJ45 ports. This guide is for the version with round connectors: the dongle is connected with two wires in the 16-pin SYS COM connector, pins 3 and 4, which Growatt has set aside for monitoring from other manufacturers.

Applies to
MIN 2500-6000TL-XH2 with round connectors
Connection
Wires in the inverter's terminal plug
Time
About 30 minutes

The battery is controlled with Growatt's VPP protocol: a command with power and duration, which the dongle removes itself when the block ends. What GridZeno can do on Growatt MIN TL-XH2

How the dongle recognises it: The type code 5100, when only the VPP ranges answer (the charge level in 31217), not the range from 3000 or 0-124.

GridZeno Dongle for Growatt MIN TL-XH2

01

What you need

GridZeno Dongle
The device ID is on the label, e.g. GZ-A1B2C3.
Cable
GridZeno's Modbus cable with one end cut off, or another network cable with one plug.
Wire strippers and ferrules
Two ferrules for the two wires in the connector.
USB power
A 5 V USB charger and a cable with USB-C.
02

The port

The round 16-pin connector on the underside between USB and AC. The same connector is used for the battery, energy meter, backup box and current clamp, so there may already be wires in it. The connector marked COM is for DRM and must not be used.

Port
SYS COM (16-pin connector)
Pin 1: Battery, Enable-.
Pin 2: Battery, Enable+.
Pin 3: A, RS485A2, blue wire.
Pin 4: B, RS485B2, white/blue wire.
Pin 5: Meter, RS485A1.
Pin 6: Meter, RS485B1.
Pin 7: Battery, BAT-B.
Pin 8: Battery, BAT-A.
Pin 9: VPP, RS485A3.
Pin 10: VPP, RS485B3.
Pin 11: Backup box, SYN.EN+.
Pin 12: Backup box, SYN.EN-.
Pin 13: not in use.
Pin 14: not in use.
Pin 15: Current clamp, CT out.
Pin 16: Current clamp, CT in.
The SYS COM connector seen from the front, with Growatt's pin numbering, from right to left in each row. Pins 3 and 4 are for monitoring from other manufacturers. The numbers are on the plug.
  • Pin 3 A, RS485A2
  • Pin 4 B, RS485B2
03

The cable

A network cable with an RJ45 plug for the dongle at one end and the other end cut off. At the inverter end, only the two wires from pins 4 and 5 are used, with ferrules on.

From the dongle to the inverter
Dongle endInverter end
Pin 4, blue (A)SYS COM pin 3, RS485A2
Pin 5, white/blue (B)SYS COM pin 4, RS485B2
The other wiresCut off and insulated
04

Settings

On the inverter

Settings > General > Address
001, as from the factory
Modbus
Modbus RTU at 9600 baud, 8N1. That's what the dongle uses from the factory, so there's nothing to set.

In GridZeno's Welcome

The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.

Manufacturer and model
Growatt, MIN
Connection
By cable (RS485)
RS485 settings
Keep the default: 9600 baud, 8N1, address 1.
05

Step by step

Each step has a small drawing that shows what to do.

  1. 1
    Check the address

    Press the touch button once to scroll, and twice to select. Go to Settings, General and Address. It should be set to 001, as from the factory.

  2. 2
    Unplug the SYS COM connector

    Switch off the inverter first: turn off the AC breaker, set the DC switch to OFF, and switch off the battery's switch. The round 16-pin connector marked SYS COM is on the underside between USB and AC. Press the catches in, and pull it out, preferably with the removal tool from the accessory bag.

  3. 3
    Prepare the cable

    Pass the cable through the connector's pressure screw, sealing ring and threaded sleeve. Strip the two wires from pin 4 (blue) and pin 5 (white/blue), and fit ferrules. Insulate the other wires.

  4. 4
    Put the wires in pins 3 and 4

    Blue (A) goes in pin 3 and white/blue (B) in pin 4, following the numbers on the connector. Pins 1, 2 and 3 are in the top row, counted from the right. Don't touch wires that are already in the other pins.

  5. 5
    Plug the connector back in

    Push the threaded sleeve into the connector, and tighten the cap. Press the connector into SYS COM until it clicks and sits firmly.

  6. 6
    Plug the RJ45 end into the dongle

    The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.

  7. 7
    Connect power to the dongle

    Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.

  8. 8
    Connect the dongle to the network

    Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.

  9. 9
    Log in, and choose your inverter

    Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Growatt MIN, and the connection By cable (RS485). Press Save inverter, and the dongle fetches its setup and reads the inverter.

The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.

06

Take care

Pins 1, 2, 7 and 8 in SYS COM are the battery's connection, 5 and 6 the energy meter's, 11 to 14 the backup box's and 15 and 16 the current clamp's. They must not be moved or connected to anything else.
If your MIN TL-XH2 has a block of six RJ45 ports on the underside instead of round connectors, use the guide for MIN TL-XH2 with RJ45.

What GridZeno can control on Growatt MIN TL-XH2, and how, is on the page about Growatt MIN TL-XH2. If you're stuck, write to us with the model name.

07

Source

Ports, pins and menus are from the manufacturer's own manual: Growatt MIN 2.5-6K TL-XH2 User Manual (GR-UM-290-A-01, EN), Section 3.1, Overview, 6.6, Signal connector, 7.2.2, Set inverter COM address, and 7.4.1, SYS COM Port.