Installation · Deye

Install GridZeno on Deye hybrid with RS485 port.

Deye's three-phase hybrid inverters for high-voltage batteries, SG01HP3 and SG02HP3, and the single-phase SG02LP1 have an RJ45 port marked RS485 for external communication. It has the same pins as the Modbus port on the other Deye models. Deye has A and B on different pins from Growatt, and uses pins 1 and 2 for other things, so the inverter end is crimped with only the three wires that are needed.

Needs an electrician: the inverter has to be opened
The inverter has to be opened to reach the Modbus port, and behind the cover are also the connections for grid, load, PV and battery. It should be done by a qualified person, e.g. an authorised installer.
Applies to
SUN-5-50K-SG01HP3, SUN-25-125K-SG02HP3 and SUN-5-12K-SG02LP1
Connection
Network cable with RJ45 plug
Time
About 25 minutes

An HP3 is controlled like a three-phase Deye, with Deye's remote control. An SG02LP1 is controlled like a single-phase one, with the inverter's time-of-use program, which the dongle saves and puts back afterwards. What GridZeno can do on Deye hybrid with RS485 port

How the dongle recognises it: Holding 0 is 0x0600, 0x0601 or 0x0602: Deye's three-phase hybrid for a high-voltage battery. The SG02LP1 hasn't been seen on a real unit yet; if it reports 0x0300, it's controlled as the single-phase LP1.

GridZeno Dongle for Deye hybrid with RS485 port

01

What you need

GridZeno Dongle
The device ID is on the label, e.g. GZ-A1B2C3.
Cable
A network cable that's re-crimped at the inverter end with only three wires.
RJ45 plug and crimping tool
For the inverter end.
USB power
A 5 V USB charger and a cable with USB-C.
02

The port

In the connection compartment at the bottom of the inverter, behind the cover, in the row of RJ45 ports together with Meter, BMS and the parallel ports. On the larger models the ports aren't labelled in the drawing, so read the names on the circuit board. The cable is passed in through a cable gland in the bottom.

Port
RS485
Pin 1: B, 485_B.
Pin 2: A, 485_A.
Pin 3: GND, GND_485.
Pin 4: not in use.
Pin 5: not in use.
Pin 6: GND, GND_485, white/green wire.
Pin 7: A, 485_A, blue wire.
Pin 8: B, 485_B, white/blue wire.
Deye's RS485 port, with Deye's pin numbering. Note that A is on pin 7 and B on pin 8. The plug shown with the contacts facing you and the locking tab at the back: pin 1 is furthest to the left.
  • Pin 7 A, 485_A
  • Pin 8 B, 485_B
  • Pin 6 GND, GND_485
03

The cable

A network cable where the inverter end is crimped with only three wires: the dongle's A on pin 7, B on pin 8 and GND on pin 6. The rest of the positions in the plug are empty. An ordinary straight cable doesn't work here.

From the dongle to the inverter
Dongle endInverter end
Dongle pin 4, blue (A)RS485 pin 7, 485_A
Dongle pin 5, white/blue (B)RS485 pin 8, 485_B
Dongle pin 3, white/green (GND)RS485 pin 6, GND_485
The other wiresCut off and insulated
04

Settings

On the inverter

Modbus SN (under Advanced Function)
Read it. The dongle must have the same address.
Baud Rate
9600, as from the factory

In GridZeno's Welcome

The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.

Manufacturer and model
Deye, Hybrid
Connection
By cable (RS485)
RS485 settings
9600 baud, 8N1, and the address from the inverter's Modbus SN.
05

Step by step

Each step has a small drawing that shows what to do.

  1. 1
    Read the inverter's Modbus address

    In the display, go to Advanced Function, to the page with Parallel, Master/Slave and Modbus SN. Note down Modbus SN. It's the inverter's address, and the dongle must have the same one. On SUN-100-125K with a touch screen, the address is under Setting, Advance and Multi-Inverter.

  2. 2
    Remove the cover from the connection compartment

    Switch off the inverter first: disconnect the battery, AC and PV. Undo the screws in the cover at the bottom of the inverter, and remove the cover. Behind it are the communication ports.

  3. 3
    Crimp the inverter end with three wires

    Cut off the plug at the inverter end. Crimp a new plug on with blue (A) on pin 7, white/blue (B) on pin 8 and white/green (GND) on pin 6. The other wires are cut off and insulated.

  4. 4
    Pass the cable in through a cable gland

    Loosen the nut on a free cable gland in the bottom of the connection compartment, and pass the cable up through it. Tighten the nut once the plug is in the port.

  5. 5
    Plug the connector into the RS485 port

    Press the plug into the port marked RS485 until it clicks. Meter is the energy meter's, and BMS is the battery's. Screw the cover back on afterwards.

  6. 6
    Plug the RJ45 end into the dongle

    The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.

  7. 7
    Connect power to the dongle

    Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.

  8. 8
    Connect the dongle to the network

    Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.

  9. 9
    Log in, and choose your inverter

    Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Deye Hybrid, and the connection By cable (RS485). If the inverter's Modbus SN isn't 1, enter the same number as Slave ID under RS485 settings. Press Save inverter, and the dongle fetches its setup and reads the inverter.

The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.

06

Take care

Use the port marked RS485. Meter is the energy meter's, and BMS is the battery's.
On SUN-SG02LP1 the RS485 port has no GND. The wire on pin 6 does no harm, but it doesn't connect anything.
If you have a Deye with a port marked Modbus, use the guide for LP3 or LP1 instead.

What GridZeno can control on Deye hybrid with RS485 port, and how, is on the page about Deye hybrid with RS485 port. If you're stuck, write to us with the model name.

07

Source

Ports, pins and menus are from the manufacturer's own manual: Deye SUN-SG01HP3, SG02HP3 and SG02LP1 User Manuals (EN, 2026), Section 3.3, Function port definition, 5.11, Advanced Function (Modbus SN), and Appendix I, Definition of RJ45 Ports.