SolaX X3-HYB G4 PRO with GridZeno.
The battery is controlled with SolaX' remote control, which stops by itself if the dongle goes silent. Applies to X3-HYB-4.0-P to 15.0-P and 10.0K-P.
What GridZeno can do on SolaX X3-HYB G4 PRO
SolaX X3-HYB G4 PRO on the compatibility list, updated 31 October 2026.
- Live overview of solar, consumption and gridAll subscriptionsWorks
- Battery state of chargeAll subscriptions · requires a batteryWorks
- Stop selling at negative pricesSmart and Pro · Requires the installer to have turned export limiting on in the inverter. GridZeno only lowers a limit that's already set.Works
- Charge from the grid when power is cheapSmart and Pro · requires a batteryWorks
- Discharge the battery when power is expensivePro · requires a batteryWorks
Works: tested and measured on real hardware.
How the inverter is controlled
The dongle controls the battery with SolaX' remote control.
- Charge, hold and sell
- A command with the battery's power and a duration. When the duration is over, the inverter stops by itself, so the battery never gets stuck in a command if the dongle goes silent.
- Stop selling at negative prices
- The inverter's export limit is set quarter by quarter by the selling price, but only where the installer has turned export limiting on. GridZeno only lowers a limit that's already set and never turns it on or off.
- Battery limits
- Your lowest state of charge is written to the inverter's own limit.
- Locked inverter
- GridZeno never unlocks the inverter. If it's locked, you unlock it in the SolaX app or in the menu. It locks itself again after a restart.
- Manual
- When the control is on Manual, the dongle changes nothing on the inverter. It reads, and if GridZeno has changed something, it puts the inverter's own settings back, including your own charge limits.
What is special about the SolaX X3-HYB G4 PRO
The serial number starts with 10K: SolaX' sixth generation, three-phase.
- Strings
- Three from 8 kW, two below. The power is characters 4-5 of the serial number.
- Firmware
- Below Modbus protocol 100, the energy counters are in 0.001 kWh and the temperature in 0.1 °C.
- The export limit
- In 10 W.
What the dongle allows for
- The BMS connection flag in 0x17 is inverted on the sixth generation and isn't used.
How it differs from its neighbours
- SolaX X1-VAST: The single-phase X1-VAST is the same generation and is controlled the same way, but the export limit is in 1 W.
- SolaX X1/X3 Hybrid G4: The Hybrid G4 is the fourth generation with the same command.
For the installer: the registers
What the dongle uses over Modbus, if you want to follow along or troubleshoot. Don't change the registers yourself while control is set to Automatic.
- Control
- One block of 8 registers from 0xA0 with function 0x10: mode 8, the battery power and a duration of 60 seconds to 8 hours. Released with 13 zeros from 0x7C.
- Export limit
- Written in 0x42 and read in 0xB6. The installer's value is saved and written back exactly as it was.
- Lowest charge level
- By the work mode in 0x8B: Self Use in 0x61, Feed-in Priority in 0x65, Backup in 0x67.
- Rated power and firmware
- The rated power in 0xBA, the Modbus protocol in 0x82.
From the dongle's firmware and our notes on each inverter, not from the datasheet.
How to connect the dongle
Network cable with RJ45 plug. Approx. 30 minutes.
- Port
- RS485 in COM1
- Pin
- A at pin 4 (REMOTE_485A), B at pin 5 (REMOTE_485B), GND at pin 6 (GND_COM)
- Where
- On the underside of the inverter, to the right of the DONGLE port. COM1 is six RJ45 ports in two columns under one shared connector housing: METER/CT, BMS1 and PARALLEL1 on the left, RS485, BMS2 and PARALLEL2 on the right. RS485 is the top one on the right.
Before you buy
This one works.