Install GridZeno on Solplanet SH 2-6 kW with RS485 cable.
The ASW SH 2-6 kW is Solplanet's single-phase hybrid. Its RJ45 port Monitor (CN710) is on the board behind the lower front cover, and Solplanet states that pins 7 and 8 are for monitoring from other manufacturers. GND is pin 3. The cable is made with only the three wires that are needed.
- Applies to
- ASW002K to 006K-SH
- Connection
- Network cable with RJ45 plug
- Time
- About 30 minutes
The battery is controlled with the inverter's operating mode. The dongle saves your own mode and puts it back afterwards. What GridZeno can do on Solplanet SH 2-6 kW with RS485 cable
How the dongle recognises it: The storage block from input 1600 can be read, so it's a hybrid, and input 1000 says single-phase.
What you need
- GridZeno Dongle
- The device ID is on the label, e.g. GZ-A1B2C3.
- Cable
- A shielded network cable, no more than 8 mm thick, re-crimped at the inverter end with only three wires.
- RJ45 plug and crimping tool
- For the inverter end.
- USB power
- A 5 V USB charger and a cable with USB-C.
The port
On the communication board behind the lower front cover. The cable is led in through the cable gland COM2, or COM1 if the cable is thicker than 6 mm.
- Port
- Monitor (CN710)
- Pin 7 A, RS485A
- Pin 8 B, RS485B
- Pin 3 GND, GND
The cable
A network cable where the inverter end is crimped with only three wires: the dongle's A on pin 7, B on pin 8 and GND on pin 3. The other positions in the connector are empty. An ordinary straight cable doesn't work here.
| Dongle end | Inverter end |
|---|---|
| Dongle pin 4, blue (A) | Solplanet pin 7, RS485A |
| Dongle pin 5, white/blue (B) | Solplanet pin 8, RS485B |
| Dongle pin 3, white/green (GND) | Solplanet pin 3, GND |
| The other wires | Cut off and insulated |
Settings
On the inverter
- Modbus address
- Solplanet's Modbus protocol uses address 3 from the factory. The manual mentions neither address nor baud rate.
In GridZeno's Welcome
The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.
- Manufacturer and model
- Solplanet, SH (RS485)
- Connection
- By cable (RS485)
- RS485 settings
- Keep the default GridZeno suggests for Solplanet (address 3).
Step by step
Each step has a small drawing that shows what to do.
- 1Turn off, and open the lower front cover
Switch off the AC breaker, and lock it. Set the DC switch to OFF, and lock it. Wait until the LEDs are off. Open the lower front cover so you can see the communication board.
- 2Pass the cable through COM2
Cut off the connector at the inverter end, and pass the cable through the cable gland COM2. If the cable is between 6 and 8 mm thick, use COM1.
- 3Crimp the inverter end with three wires
Crimp on a new connector with blue (A) on pin 7, white/blue (B) on pin 8 and white/green (GND) on pin 3. The other wires are cut off and insulated.
- 4Plug the connector into CN710
Press the connector into the Monitor port (CN710) on the board until it clicks. Close the front cover, and tighten the cable gland.
- 5Plug the RJ45 end into the dongle
The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.
- 6Connect power to the dongle
Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.
- 7Connect the dongle to the network
Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.
- 8Log in, and choose your inverter
Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Solplanet SH (RS485), and the connection By cable (RS485). Press Save inverter, and the dongle fetches its setup and reads the inverter.
The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.
Take care
What GridZeno can control on Solplanet SH 2-6 kW with RS485 cable, and how, is on the page about Solplanet SH 2-6 kW with RS485 cable. If you're stuck, write to us with the model name.
Source
Ports, pins and menus are from the manufacturer's own manual: Solplanet UM0094 ASW002-006K-SH-EUAU User Manual (EN, V01), The pin tables for the board's RJ45 ports (CN710, Monitor) and the cable glands COM1 and COM2.