Install GridZeno on Sofar HYD-T1.
HYD-T1 is Sofar's large three-phase hybrid inverter for business and farming. The communication ports are gathered behind one COM housing: six RJ45 ports and a terminal block. Sofar's RS485 for monitoring is pins 1 and 2 in Link0 and Link1, and GND on pin 3. The cable is made with only the three wires that are used.
- Applies to
- HYD-40K, 49.9K-A, 50K and 60K-T1
- Connection
- Network cable with RJ45 plug
- Time
- About 30 minutes
What GridZeno can do on Sofar HYD-T1 today
There's no public register map for the HYD 40-60K-T1, so the dongle can't read it yet.
- Live overview of solar, consumption and gridAll subscriptionsComing later
- Battery state of chargeAll subscriptionsComing later
- Stop selling at negative pricesSmart and ProComing later
- Charge from the grid when power is cheapSmart and ProComing later
- Discharge the battery when power is expensiveProComing later
You can connect the dongle by this guide, but it reads nothing from the inverter until its firmware can. GridZeno Dongle for Sofar HYD-T1
What you need
- GridZeno Dongle
- The device ID is on the label, e.g. GZ-A1B2C3.
- Cable
- A network cable that's re-crimped at the inverter end with only three wires.
- RJ45 plug and crimping tool
- For the inverter end.
- USB power
- A 5 V USB charger and a cable with USB-C.
The port
On the underside of the inverter, between the PV inputs and the Wi-Fi/4G port. Behind the COM housing's cable gland the ports are in three rows: BMS and Ethernet, Meter/CT and DRMs, Link0 and Link1.
- Port
- Link0 or Link1 in the COM housing
- Pin 1 A, RS485 A
- Pin 2 B, RS485 B
- Pin 3 GND, GND_S
The cable
A network cable where the inverter end is crimped with only three wires: the dongle's A on pin 1, B on pin 2 and GND on pin 3. The other positions in the connector are empty. An ordinary straight cable doesn't work here.
| Dongle end | Inverter end |
|---|---|
| Dongle pin 4, blue (A) | Sofar pin 1, RS485 A |
| Dongle pin 5, white/blue (B) | Sofar pin 2, RS485 B |
| Dongle pin 3, white/green (GND) | Sofar pin 3, GND_S |
| The other wires | Cut off and insulated |
Settings
On the inverter
- The Modbus address on the display
- Read the inverter's Modbus address (1 to 31) and baud rate. The dongle must have the same. The manual doesn't show the menu or the default.
In GridZeno's Welcome
The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.
- Manufacturer and model
- Sofar Solar, HYD-T1
- Connection
- By cable (RS485)
- RS485 settings
- Same baud rate and address as the inverter, 8N1. Start with 9600 and 1 if you can't find them.
Step by step
Each step has a small drawing that shows what to do.
- 1Read off the address and baud rate
Find the inverter's Modbus address and baud rate on the display. Each inverter has its own address from 1 to 31. Note them down: the dongle must have the same. Advanced Settings requires the password 0715.
- 2Pass the cable through the COM housing
Switch off the inverter first: choose Switch Off in the menu, switch off the grid and backup breakers, set the PV switch to OFF, switch off the battery, and wait 5 minutes. Remove the rubber plug from the hole in the COM housing's seal that you're going to use, and pass the cable through the cable gland, the clip and the hole.
- 3Crimp the inverter end with three wires
Cut off the plug at the inverter end. Crimp on a new plug with blue (A) on pin 1, white/blue (B) on pin 2 and white/green (GND) on pin 3. The other wires are cut off and insulated.
- 4Insert the plug in a free Link port
Push the plug into Link0 or Link1, whichever is free, until it clicks, and lock the COM housing back on. If there's a termination resistor in the free port, write to us before you remove it.
- 5Plug the RJ45 end into the dongle
The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.
- 6Connect power to the dongle
Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.
- 7Connect the dongle to the network
Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.
- 8Log in, and choose your inverter
Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Sofar Solar HYD-T1, and the connection By cable (RS485). Set the inverter's baud rate and address under RS485 settings. Press Save inverter, and the dongle fetches its setup and reads the inverter.
The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.
Take care
Sofar HYD-T1 isn't on the compatibility list yet. If you're stuck, write to us with the model name.
Source
Ports, pins and menus are from the manufacturer's own manual: Sofar HYD-40-60K-T1 User Manual V1.1 (EN, 2026-03), Section 5, COM (figure 5-20, the Link0/Link1 table) and parallel connection (figures 5-28 and 5-29).