Install GridZeno on Sofar ESI-T1.
ESI-T1 is Sofar's three-phase hybrid inverter, stacked with BTS batteries. The communication ports are gathered behind one COM housing: six RJ45 ports and a terminal block. Sofar's RS485 for monitoring is pins 1 and 2 in the Link0 port, which is also used for inverters in parallel. The cable is made with only the two wires that are used.
- Applies to
- ESI-5K to ESI-12K-T1
- Connection
- Network cable with RJ45 plug
- Time
- About 25 minutes
What GridZeno can do on Sofar ESI-T1 today
There's no public register map for the ESI 5-12K-T1, so the dongle can't read it yet.
- Live overview of solar, consumption and gridAll subscriptionsComing later
- Battery state of chargeAll subscriptionsComing later
- Stop selling at negative pricesSmart and ProComing later
- Charge from the grid when power is cheapSmart and ProComing later
- Discharge the battery when power is expensiveProComing later
You can connect the dongle by this guide, but it reads nothing from the inverter until its firmware can. GridZeno Dongle for Sofar ESI-T1
What you need
- GridZeno Dongle
- The device ID is on the label, e.g. GZ-A1B2C3.
- Cable
- A network cable that's re-crimped at the inverter end with only two wires.
- RJ45 plug and crimping tool
- For the inverter end.
- USB power
- A 5 V USB charger and a cable with USB-C.
The port
On the side of the inverter, behind the COM housing's cable gland. The ports are in three rows: Wall Box and Ethernet, Meter/CT and DRMs, Link0 and Link1. Below them is the Dry & Wet Contact terminal block.
- Port
- Link0 in the COM housing
- Pin 1 A, RS485 A
- Pin 2 B, RS485 B
The cable
A network cable where the inverter end is crimped with only two wires: the dongle's A on pin 1 and B on pin 2. The rest of the positions in the plug are empty. An ordinary straight cable doesn't work here.
| Dongle end | Inverter end |
|---|---|
| Dongle pin 4, blue (A) | Sofar pin 1, RS485 A |
| Dongle pin 5, white/blue (B) | Sofar pin 2, RS485 B |
| The other wires | Cut off and insulated |
Settings
On the inverter
- System Settings > 6. RS485 Communication
- Modbus address 01 and baud rate 9600, as from the factory.
In GridZeno's Welcome
The inverter is chosen in GridZeno: in Welcome the first time, and later under System, Change inverter. The dongle fetches its setup from there.
- Manufacturer and model
- Sofar Solar, ESI-T1
- Connection
- By cable (RS485)
- RS485 settings
- Keep the default: 9600 baud, 8N1, address 1.
Step by step
Each step has a small drawing that shows what to do.
- 1Check address and baud rate
On the display, go to System Settings and 6. RS485 Communication. The address must be 01 and the baud rate 9600, as from the factory.
- 2Pass the cable through the COM housing
Switch off the inverter first: choose Advanced Settings, Switch On/Off, Switch Off, switch off the grid and load breakers, set the PV switch to OFF, switch off the battery, and wait 5 minutes. Remove the rubber plug from the hole in the COM housing's seal that you're going to use, and pass the cable through the cable gland, the clip and the hole.
- 3Crimp the inverter end with two wires
Cut off the plug at the inverter end. Crimp a new plug on with blue (A) on pin 1 and white/blue (B) on pin 2. The other wires are cut off and insulated.
- 4Insert the plug in Link0
Push the plug into the Link0 port until it clicks, and lock the COM housing back on. If the inverter is in parallel with others, use the Link port that's free.
- 5Plug the RJ45 end into the dongle
The cable's other end goes into the dongle's RS485 port. Place the dongle somewhere dry and close to the inverter, so the cable doesn't hang from the plug.
- 6Connect power to the dongle
Plug the USB-C cable into the dongle and the charger into a socket. The dongle starts by itself. It gets power from the charger, not from the inverter.
- 7Connect the dongle to the network
Over Wi-Fi: the first time, the dongle creates its own Wi-Fi, GridZeno-Setup- followed by the last characters of the device ID. Connect your phone to it, choose your own network, enter the password, and press Save and connect. When it says Connection OK, press Go to GridZeno. Over cable (LAN): plug a network cable from the router into the dongle's network port.
- 8Log in, and choose your inverter
Log in to GridZeno. Welcome pairs the dongle with its device ID. Then choose your inverter, Sofar Solar ESI-T1, and the connection By cable (RS485). Press Save inverter, and the dongle fetches its setup and reads the inverter.
The dongle's own setup is described with screenshots in The user guide, and the pairing in Getting started.
Take care
Sofar ESI-T1 isn't on the compatibility list yet. If you're stuck, write to us with the model name.
Source
Ports, pins and menus are from the manufacturer's own manual: Sofar ESI 5-12K-T1 User Manual V1.9 (EN, 2026-02), Section 5.6, Communication connection (figure 5-25, the Link0/Link1 table), and System Settings, 6. RS485 Communication.