Compatibility · Ready for GridZeno
SolaX X3-PRO with GridZeno.
A grid inverter without a battery. GridZeno shows what it produces but can't control anything on it. Applies to X3-PRO 8-30K-G2.
01
What GridZeno can do on SolaX X3-PRO
SolaX X3-PRO on the compatibility list, updated 31 October 2026.
- Live overview of solar, consumption and gridAll subscriptions · Grid and consumption require an energy meter on the inverter and a firmware that shows it. Otherwise solar production only.Works
- Battery state of chargeAll subscriptions · requires a battery · The grid inverter has no battery.Not possible
- Stop selling at negative pricesSmart and Pro · SolaX' protocol has no export limit on this inverter.Not possible
- Charge from the grid when power is cheapSmart and Pro · requires a batteryNot possible
- Discharge the battery when power is expensivePro · requires a batteryNot possible
Works: tested and measured on real hardware.
02
How the inverter is controlled
The dongle reads the inverter and never writes anything to it.
- What GridZeno reads
- Solar production, and grid and consumption when there's an energy meter on the inverter.
- Battery
- None. The inverter is a grid inverter without a battery, so there's nothing to charge or sell from.
- Grid export
- SolaX' protocol has no export limit on this inverter, so GridZeno can't stop the sale.
Manual means no switching
When the control is on Manual, GridZeno calculates the plan and shows it, but changes nothing on the inverter.
03
What is special about the SolaX X3-PRO
The serial number in holding 0x300 starts with MP156T or MPT: X3-PRO G2.
- What the dongle reads
- Input 0x400-0x434, with PV3 in 0x42B, and the meter from 0x43B. The PRO 12-30 kW has three strings. The rated power from the machine type in 0x34E.
- Export limit
- None in SolaX' official maps. The power limits limit the whole output and aren't used.
How it differs from its neighbours
- SolaX X3-MIC: The X3-MIC G2 is read the same way, but is connected in the RJ45 port RS485 with pins 4 and 5.
From the dongle's firmware and our notes on each inverter, not from the datasheet.
04
How to connect the dongle
Wires in the inverter's terminal plug. Approx. 30 minutes.
- Port
- RS485 terminal (6-pin terminal block)
- Pin
- A at terminal a (a, 485A), B at terminal b (b, 485B)
- Where
- On the underside of the inverter, under a cover next to the COM port. The cable is passed in through a nut with a plug.
05
Before you buy
This one works.
SolaX X3-PRO is the inverter GridZeno has been tested on. Check that your model is under X3-PRO 8-30K-G2. If it still doesn't suit you, you have 100 days' free return.