SolaX X3-MEGA G2, X3-FORTH, FORTH G3, X3-GRAND HV with GridZeno.
Large grid inverters without a battery. GridZeno shows the solar production on an X3-MEGA G2 and X3-FORTH but can't control anything on them. Applies to X3-MGA-20K to 60K-G2, X3-FTH-40K to 150K, FTH80T to 125T and X3-GRD-300K to 350K-HV.
What GridZeno can do on SolaX X3-MEGA G2, X3-FORTH, FORTH G3, X3-GRAND HV
SolaX X3-MEGA G2, X3-FORTH, FORTH G3, X3-GRAND HV on the compatibility list, updated 31 October 2026.
- Live overview of solar, consumption and gridAll subscriptions · Solar production only. The dongle can't read a FORTH G3 or an X3-GRAND HV yet.Works
- Battery state of chargeAll subscriptions · requires a battery · The grid inverter has no battery.Not possible
- Stop selling at negative pricesSmart and Pro · The inverter only has a limit for the whole output, and the dongle doesn't use it yet.Coming later
- Charge from the grid when power is cheapSmart and Pro · requires a batteryNot possible
- Discharge the battery when power is expensivePro · requires a batteryNot possible
Works: tested and measured on real hardware.
How the inverter is controlled
The dongle reads the inverter and never writes anything to it.
- What GridZeno reads
- Solar production on an X3-MEGA G2 and X3-FORTH. Grid and consumption aren't shown. The dongle can't read a FORTH G3 or an X3-GRAND HV yet.
- Battery
- None. The inverter is a grid inverter without a battery, so there's nothing to charge or sell from.
- Grid export
- The inverter only has a limit for the whole output, and the dongle doesn't use it yet.
What is special about the SolaX X3-MEGA G2, X3-FORTH, FORTH G3, X3-GRAND HV
The serial number is in input 0x32, not in holding 0x00: X3G04, X3G05, X3G06, X3G075, X3G08, X3G01, A3F10 or MAXMEG_G2. The X3-FORTH G3 and X3-GRAND HV have no public register map and aren't recognised yet.
- What the dongle reads
- The AC power in 0x183, today's and the total production in 0x189 and 0x18A, the temperature in 0x202 and all 12 MPPTs from 0x28D in one read of 84 registers.
- Byte order
- High word first, the opposite of SolaX' other maps.
- Limits
- No meter and no battery. The power limit in 0x2304 limits the whole output and isn't used.
How it differs from its neighbours
- SolaX X3-PRO: The X3-PRO G2 is read in another range and has a meter from 0x43B.
From the dongle's firmware and our notes on each inverter, not from the datasheet.
How to connect the dongle
Wires in the inverter's terminal plug. Approx. 30 minutes.
- Port
- COM (30-pin connector)
- Pin
- A at pin 1 (RS485A IN+), B at pin 2 (RS485B IN-), GND at pin 3 (IN-GND (reserved on X3-FORTH))
- Where
- The round, waterproof COM connector on the underside of the inverter, by the Dongle port. The same connector is used for energy meter and DRM, so there may already be wires in it.
See the full installation guide for SolaX X3-MEGA G2, X3-FORTH, FORTH G3, X3-GRAND HV