Growatt MIN TL-XH2 (RJ45) with GridZeno.
The battery is controlled with Growatt's VPP protocol: a command with power and duration, which the dongle removes itself when the block ends. Applies to MIN 2500-6000TL-XH2 with six RJ45 ports.
What GridZeno can do on Growatt MIN TL-XH2 (RJ45)
Growatt MIN TL-XH2 (RJ45) on the compatibility list, updated 31 October 2026.
- Live overview of solar, consumption and gridAll subscriptions · The grid is shown once the inverter's energy meter has measured something since restart.Works
- Battery state of chargeAll subscriptions · requires a batteryWorks
- Stop selling at negative pricesSmart and Pro · Requires the installer to have turned export limiting on in the inverter. GridZeno only lowers a limit that's already set.Works
- Charge from the grid when power is cheapSmart and Pro · requires a battery · Requires Growatt's VPP protocol V2.01 in the inverter's firmware. Without it, GridZeno can only read and limit the export.Works
- Discharge the battery when power is expensivePro · requires a battery · Requires Growatt's VPP protocol V2.01 in the inverter's firmware. Without it, GridZeno can only read and limit the export.Works
Works: tested and measured on real hardware.
How the inverter is controlled
The dongle controls the battery with Growatt's VPP protocol.
- Charge, hold and sell
- A command with the battery's power and a duration. The dongle removes it itself when the block ends, and after a restart.
- What it requires
- VPP V2.01 in the inverter's firmware. Without it, GridZeno can only read the inverter and limit the sale.
- Stop selling at negative prices
- The inverter's export limit is set quarter by quarter by the selling price, but only where the installer has turned export limiting on. GridZeno only lowers a limit that's already set and never turns it on or off.
- Another controller
- If another system already has a VPP command on the inverter, the dongle leaves it alone and doesn't control the inverter.
- Manual
- When the control is on Manual, the dongle changes nothing on the inverter. It reads, and if GridZeno has changed something, it puts the inverter's own settings back, including your own charge limits.
What is special about the Growatt MIN TL-XH2 (RJ45)
The type code 5100, when only the VPP ranges answer (the charge level in 31217), not the range from 3000 or 0-124.
- What it requires
- VPP V2.01 in the inverter's firmware (holding 30099 = 201).
- State of charge limits
- 30404 takes only 70-100 % and 30405 only 10-30 %. Your limits are fitted into those ranges, and the plan itself holds the battery at your lowest charge level.
- The grid
- Read in the meter, 31112, not in 31100. Until 31112 has shown something other than 0, the inverter reports no grid.
How it differs from its neighbours
- Growatt MIN TL-XH2: The same inverter with round connectors. The dongle controls it the same way; the difference is the port: pins 3 and 4 in the 16-pin SYS COM connector.
For the installer: the registers
What the dongle uses over Modbus, if you want to follow along or troubleshoot. Don't change the registers yourself while control is set to Automatic.
- Control
- The VPP command in 30407-30410: 30408 is the duration, 30409 the power in per cent, 30410 = 1 when charging. 30100 = 1 turns it on. The dongle writes in the order 30408, 30409, 30410, 30100, 30407 and removes it with 30407 = 0, 30409 = 0, 30410 back and 30100 = 0.
- Protocol
- Holding 30099 shows the VPP version: 201 is V2.01.
- State of charge limits
- 30404 (highest, 70-100) and 30405 (lowest, 10-30).
- Export limit
- 30201 in whole per cent, when the installer has set 30200 = 1.
From the dongle's firmware and our notes on each inverter, not from the datasheet.
How to connect the dongle
Network cable with RJ45 plug. Approx. 25 minutes.
- Port
- SYN
- Pin
- A at pin 3 (RS485A2), B at pin 6 (RS485B2)
- Where
- In the block of six RJ45 ports on the underside, under the waterproof cover: DRMS and COM at the top, BAT and Meter in the middle, SYN and RS485 at the bottom.
See the full installation guide for Growatt MIN TL-XH2 (RJ45)
Before you buy
This one works.
Growatt MIN TL-XH2 (RJ45) is the inverter GridZeno has been tested on. Check that your model is under MIN 2500-6000TL-XH2 with six RJ45 ports, and that a battery is fitted if you want the battery controlled by the electricity price. If it still doesn't suit you, you have 100 days' free return.